Predictive Maintenance

Using sensor data and machine learning to predict when equipment is likely to fail, so maintenance can be scheduled before a breakdown.

Models learn the normal patterns of vibration, temperature and load, then flag anomalies early. Read How AI Predictive Maintenance Saves Manufacturers Millions.

How it works

Sensors on equipment record signals such as vibration, temperature and power use. A model learns what normal running looks like for each machine and raises an alert when the pattern starts to change, often long before a breakdown.

What to watch

Alerts are only useful if the maintenance team trusts them, so the first weeks should compare alerts with what technicians actually find.

Predictive Maintenance in depth

From sensors to a work order

A predictive maintenance system is a chain, and each link needs attention:

  1. Choose the assets. Start with equipment where failures are costly, happen often enough to learn from, and give warning signs, such as motors, pumps, compressors and conveyors.
  2. Collect signals. Vibration, temperature, current draw, pressure and run hours, from existing PLCs and SCADA systems through protocols such as OPC UA or Modbus, or from added wireless sensors.
  3. Bring in maintenance history. Work orders, failure codes and parts replaced from the CMMS or ERP give the labels a model needs.
  4. Model. Begin with anomaly detection per machine, then move to failure-mode classification or remaining-useful-life estimates where history supports it.
  5. Act. Alerts create a draft work order with the evidence attached, and a planner decides whether to schedule it.
  6. Close the loop. Technicians record what they found, which becomes feedback for the model.

Example: a pump fleet

Example: a water utility runs dozens of pumps across sites. Existing SCADA data includes flow, pressure and motor current at one-minute intervals; vibration sensors are added to the most critical units. For each pump, a model learns normal relationships, such as current draw for a given flow, and flags sustained deviations rather than single spikes. When a pump drifts, the planner sees a trend chart, the likely cause based on similar past cases, and a draft work order. For the first months, every alert is reviewed with technicians, and the team records whether a real issue was found, so the threshold can be tuned to the level of alerts the maintenance team can act on.

Choosing a modeling approach

Data availableApproach
Sensor data, few recorded failuresAnomaly detection against each machine's normal pattern
Labeled failure modesClassification of developing faults
Run-to-failure historiesRemaining useful life estimation
Very little dataRules from engineering limits, then collect data

Physics and engineering knowledge improves every approach. Features such as vibration frequency bands linked to bearing faults often beat raw signals, and maintenance engineers should help design them. Our forecasting and predictive analytics work uses the same time-series foundations.

Measuring success

  • Alert precision: share of alerts where technicians found a real issue.
  • Lead time: how far ahead of failure alerts arrive, which decides whether planning is possible.
  • Missed failures: breakdowns with no prior alert.
  • Operational outcomes: unplanned downtime, emergency repairs and spare-parts usage, compared with a baseline period before launch.

Agree the baseline period and data sources with operations before the pilot, so the comparison is fair.

Common mistakes

Typical problems are starting with assets that rarely fail, too many alerts in the first weeks so technicians stop trusting the system, maintenance records too inconsistent to use as labels, and models that live in a dashboard nobody opens instead of in the work order system. Predictive maintenance is an application of machine learning and depends on MLOps for monitoring and retraining. See the predictive maintenance solution and manufacturing pages for how we approach it.

Questions about Predictive Maintenance

Something else? Send us your question and an engineer replies with next steps.

Do we need new sensors to start predictive maintenance?

Not always. Many plants already collect useful data in PLCs, SCADA historians and energy meters, such as motor current, temperature and pressure. Starting with existing data shows what is possible at lower effort. Vibration sensors are often added for rotating equipment because vibration gives early warning of bearing and alignment faults. A short data audit of what is recorded, how often and for how long is a good first step.

How is predictive maintenance different from preventive maintenance?

Preventive maintenance follows a fixed schedule, such as servicing every set number of run hours, whether the machine needs it or not. Predictive maintenance uses the machine's actual condition to decide when work is needed. It can avoid unnecessary servicing and catch problems that develop between scheduled visits. Most plants keep a preventive schedule for safety-critical tasks and add predictive monitoring on top.

Articles that mention Predictive Maintenance

All articles

Jump to

↑↓ to move↵ to open