AI predictive maintenance

We build predictive maintenance models that move teams from reactive repairs to planned maintenance. They analyze sensor data such as vibration and temperature to predict failures before they happen and recommends the best maintenance windows.

What we build

The parts of the system our engineers design, build and connect to your tools. Your team owns the code, prompts and models.

  • Real-time monitoring of IoT sensor data

  • Anomaly detection and failure prediction

  • Maintenance alerts with recommended actions

  • Optimal scheduling windows

  • Predictions inside your existing dashboards

How a project runs

A fixed-scope plan first, then weekly releases you can see.

  1. 1

    Connect sensor data

    We connect your machine and sensor data streams.

  2. 2

    Model failures

    Models learn the patterns that precede failures.

  3. 3

    Alert and schedule

    Your team gets alerts and recommended maintenance windows.

Predictive maintenance in depth

From sensor signal to work order

Machines produce signals: vibration, temperature, current draw, pressure, oil quality, cycle counts, alarms from the PLC. Edge gateways collect these over industrial protocols such as OPC UA or Modbus, buffer them when the network drops and send them to a time-series store. Sampling rates matter: bearing faults may need high-frequency vibration data that is summarized at the edge into spectral features, while temperature trends need only a reading every few seconds.

Models run on the incoming data in two layers. Anomaly detection learns what normal looks like for each asset in each operating mode and flags departures. Where enough failure history exists, failure models estimate the likelihood of a specific failure mode or the remaining useful life. When a threshold is crossed, the system creates an alert with the evidence: the signal trend, similar past events and the likely failure mode. A maintenance planner reviews it and decides whether to raise a work order in your CMMS or ERP, inspect, or watch.

Data you need, and what to do if failure history is thin

Useful inputs are sensor streams, asset master data (make, model, install date, location), maintenance and work-order history with failure codes, operating context (load, speed, product being run, shift) and environmental data where relevant. The hardest gap is usually failure labels: work orders that say "repaired" without saying what failed or when it started.

Few plants have many recorded failures of the same type, which is good for operations and hard for supervised models. We handle this in three ways: start with anomaly detection that needs only normal data, use physics and engineering rules from your maintenance team (for example known vibration frequencies for bearing defects), and improve labeling going forward so each work order records the failure mode. Over time the system gathers the history that supervised models need. For a primer, see our glossary entry on predictive maintenance.

Choosing an approach

ApproachWhen it fitsLimits
Condition thresholds and rulesWell-understood failure modes with known limitsMisses gradual or combined patterns; tends to raise many alerts
Anomaly detection per assetLittle failure history, many sensorsSays something is unusual, not what will fail
Supervised failure and remaining-life modelsRepeated failures of the same type with good labelsNeeds history and careful validation across assets
Hybrid with engineering rulesMost plantsMore design work up front, but alerts are explainable

Inference can run in the cloud, on an on-premises server or at the edge. Edge inference suits sites with weak connectivity or fast-acting protection needs; cloud suits fleet-wide comparison and model training. Many deployments do both.

Architecture at a glance

The system has four layers. At the edge, gateways read machine data, compute features such as vibration spectra and buffer readings during network outages. A data layer stores raw and feature data in a time-series database alongside asset and maintenance records. A model layer trains per-asset or per-class models on historical data, runs scoring on new data and keeps versions of every model so an alert can be traced to the model that raised it. An application layer shows asset health, alerts, evidence and planner feedback, and writes approved actions to the maintenance system. Each layer can sit on the cloud, on premises or split between them, and we pick based on connectivity, data volume and your IT and OT security rules.

Integrations

Alerts are only useful if they land where maintenance teams already work. We connect to historians and SCADA for data, to a CMMS or ERP plant maintenance module (for example SAP) for asset records and work orders, and to dashboards your team already uses. Spare-part availability can be checked when an alert is raised, so planners see whether the part is in stock before scheduling a stop. See SAP integration, predictive analytics and AI for manufacturing.

Metrics to baseline

  • Unplanned downtime per asset class, from your maintenance records over a recent period.
  • Mean time between failures and mean time to repair for the assets in scope.
  • Alert precision: share of alerts that planners judged useful after inspection, tracked from the first day.
  • Lead time: how far ahead of a failure the first credible alert appeared.
  • Planned versus unplanned maintenance ratio and emergency spare-part orders.

Alert precision and lead time are the early signals. Downtime and maintenance ratios move more slowly and need comparison against the same assets and season.

Rollout, risks and controls

We start with one asset class that fails often enough to matter and has sensors already installed, such as motors, pumps, compressors or spindles on one line. The first stage is silent: models run and alerts are logged but not sent, and we compare them against what actually happened. Next, alerts go to one planner who rates each one. Wider rollout follows when planners trust the alerts.

The biggest operational risk is alert fatigue: too many alerts and planners stop looking. We tune thresholds with the planners, group related alerts into one case and suppress alerts during known events such as changeovers. Model drift after equipment changes or new product runs is monitored, and retraining is reviewed before release. On the security side, OT networks stay separated from IT: gateways push data out through one controlled path, and the system never writes commands back to machines. Predictive maintenance usually involves machine data rather than personal data, but operator IDs in shift logs are personal data under India's DPDP Act 2023 and are minimized or pseudonymized.

Questions about predictive maintenance

Something else? Send us your question and an engineer replies with next steps.

What data do we need?

Operational and sensor data from your equipment, such as vibration and temperature, plus your maintenance history.

How long until we see results?

A focused AI agent or integration typically takes 4–8 weeks from kickoff to deployment. You see a first working version in the second or third week of the pilot.

Do we need to install new sensors?

Not always. Many machines already log temperature, current, pressure and alarms through PLCs or a historian, and that may be enough for a first model. For rotating equipment, vibration sensors often add the most value. We review your existing data during discovery and recommend sensors only for the assets and failure modes where current data cannot give useful warning.

Can it work with older machines that have no connectivity?

Yes, through retrofit sensors and edge gateways that clamp on or mount to the machine and send data over the plant network or a cellular link. Older equipment is often where unplanned failures hurt most. We keep the retrofit simple and separate from machine controls, so nothing changes in how the machine itself operates.

Will the system stop a machine automatically?

No. We design it to inform people, not to control equipment. It raises alerts with evidence and a recommended action, and your maintenance team decides whether to inspect, schedule a stop or keep running. Safety protections that already exist in the machine or PLC remain the only automatic trips.

How do you avoid flooding planners with false alarms?

We start with alerts logged silently and compare them with what actually happened, then tune thresholds with your planners before anyone is notified. Related alerts are grouped into one case, known events such as changeovers are suppressed, and every alert is rated by the planner, which feeds back into tuning. Alert precision is tracked as a core metric.

Jump to